Unfortunately this page does not have a mobile or narrow screen view. Please switch to a desktop computer or increase the size of your browser. For tablets try flipping the screen.
Data Publication
Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample
Van Offenwert, Stefanie | Cnudde, Veerle | Ellman, Sharon | Bultreys, Tom
YoDa Data Repository, Utrecht University, Netherlands
(2024)
This dataset was used in the study of Van Offenwert et al. (2024). It contains time-resolved laboratory-based micro-CT images of saturated and unsaturated solute injection experiments in sintered glass and Bentheimer sandstone. Based on the grey values in the resolved pore space, pore-scale concentration fields can be quantified. The tracer injection experiments were imaged at 15 s per scan with a voxel size of 13.0 µm (‘Tracer injection experiments’). Each fast imaging experiment was preceded by a higher quality slower pre-scan to determine the static pore structure. All data were acquired with a gantry-based micro-CT system specially designed for in-situ imaging (UGCT). The aim was to analyze pore-scale solute concentration fields to investigate solute spreading and mixing during tracer injection experiments. Further details on the analyses of the micro-CT images can be found in Van Offenwert et al. (2024). The dataset can be used to investigate the influence of pore-scale heterogeneity and the volumetric pump velocity (the Péclet number) on transport processes. The data is provided in 2 subfolders. Detailed information about the files in these subfolders as well as information on how the data is processed is given in the explanatory file ReadMe_Yoda_VanOffenwert.txt. Contact person is Stefanie van Offenwert - stefanie.vanoffenwert@ugent.be.
Keywords
Originally assigned keywords
MSL enriched keywords
MSL enriched sub domains i
Source publisher
YoDa Data Repository, Utrecht University, Netherlands
DOI
10.24416/uu01-l5ltra
Authors
Van Offenwert, Stefanie
0000-0003-1144-9471
Ghent University;
Cnudde, Veerle
0000-0002-3269-5914
Utrecht University; Ghent University;
Ellman, Sharon
0000-0002-1503-4145
Ghent University;
Bultreys, Tom
0000-0001-8217-8053
Ghent University;
References
References
Citiation
Van Offenwert, S., Cnudde, V., Ellman, S., & Bultreys, T. (2024). Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample (Version 1.0) [Data set]. Utrecht University. https://doi.org/10.24416/UU01-L5LTRA
Collection Period
2020-08-28 - 2020-09-15
Geo location(s)
UGent Core facility UGCT, Ghent, Belgium