Unfortunately this page does not have a mobile or narrow screen view. Please switch to a desktop computer or increase the size of your browser. For tablets try flipping the screen.

Data Publication

Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample

Van Offenwert, Stefanie | Cnudde, Veerle | Ellman, Sharon | Bultreys, Tom

YoDa Data Repository, Utrecht University, Netherlands

(2024)

This dataset was used in the study of Van Offenwert et al. (2024). It contains time-resolved laboratory-based micro-CT images of saturated and unsaturated solute injection experiments in sintered glass and Bentheimer sandstone. Based on the grey values in the resolved pore space, pore-scale concentration fields can be quantified. The tracer injection experiments were imaged at 15 s per scan with a voxel size of 13.0 µm (‘Tracer injection experiments’). Each fast imaging experiment was preceded by a higher quality slower pre-scan to determine the static pore structure. All data were acquired with a gantry-based micro-CT system specially designed for in-situ imaging (UGCT). The aim was to analyze pore-scale solute concentration fields to investigate solute spreading and mixing during tracer injection experiments. Further details on the analyses of the micro-CT images can be found in Van Offenwert et al. (2024). The dataset can be used to investigate the influence of pore-scale heterogeneity and the volumetric pump velocity (the Péclet number) on transport processes. The data is provided in 2 subfolders. Detailed information about the files in these subfolders as well as information on how the data is processed is given in the explanatory file ReadMe_Yoda_VanOffenwert.txt. Contact person is Stefanie van Offenwert - stefanie.vanoffenwert@ugent.be.

Keywords


Originally assigned keywords
Natural Sciences Earth and related environmental sciences 15
Microcomputed Tomography
NonFickian solute transport
unsaturated flow and transport
porescale imaging
sintered glass
Bentheimer sandstone
microCT image
tracer injection experiments
Pclet number

MSL enriched keywords
sedimentary rock
sandstone
Technique
imaging (3D)
computed tomography (CT)

MSL enriched sub domains i

microscopy and tomography


Source publisher

YoDa Data Repository, Utrecht University, Netherlands


DOI

10.24416/uu01-l5ltra


Authors

Van Offenwert, Stefanie

0000-0003-1144-9471

Ghent University;

Cnudde, Veerle

0000-0002-3269-5914

Utrecht University; Ghent University;

Ellman, Sharon

0000-0002-1503-4145

Ghent University;

Bultreys, Tom

0000-0001-8217-8053

Ghent University;


References

References


Citiation

Van Offenwert, S., Cnudde, V., Ellman, S., & Bultreys, T. (2024). Micro-computed tomography data of solute transport in a saturated and unsaturated sintered glass and Bentheimer sandstone sample (Version 1.0) [Data set]. Utrecht University. https://doi.org/10.24416/UU01-L5LTRA


Collection Period

2020-08-28 - 2020-09-15


Geo location(s)

UGent Core facility UGCT, Ghent, Belgium